Rx/TA DPL Invert |
(Conventional MPL Configuration, MPL List) |
![]()
Selects for Digital Private Line (DPL) signals to be inverted when they are received by the radio while operating on the current MPL (Multiple Private Line) List - (record / row). Inverted coding allows for more traffic / usage on frequencies.
![]()
|
When the Direct Frequency field is enabled, the MPL Direct / Talkaround parameters can then be modified on a per MPL List basis. Once modified, the radio may then be transmitting and receiving on a different carrier frequency and or frequency parameters while operating in Direct / Talkaround mode. |
|
When the Direct Frequency field is disabled, the settings for MPL Rx parameter fields are also used for Direct Talkaround functionality. Therefore when in Direct / Talkaround mode, the radio is transmitting and receiving on the same carrier frequency and frequency parameters. |
|
|
![]()
|
DPL Invert must be set on both receiving and transmitting radios for communication to occur. |
|
The MPL menu can only be accessed by the radio-user when the radio is operating on a Conventional communications channel that has its Rx Voice / Signal Type field set to "Non-ASTRO", and has its User Selectable PL [MPL] field enabled. |
|
|
![]()
When Rx / TA Squelch Type is set to "DPL", and
when the radio is model / option capable.